, , , , ,

Contec ECG 1200G (12 Channel)

Payment Methods

  • x 3 Months
    Full:
Description Contec ECG 1200G (12 Channel) Contec ECG 1200G (12 Channel) Descriptions: The ECG 1200G is an electrocardiograph that can concurrently capture 12-lead ECG signals and print an ECG waveform using a thermal printing method. In AUTO or MANUAL mode, the ECG waveform is recorded and displayed. ECG waveform characteristics are automatically measured and diagnosed. “Lead off” and “Lack of paper” prompts. The ECG 1200G is an electrocardiograph that can collect 12-lead ECG signals while also printing an ECG waveform using thermal printing. It includes features such as recording and displaying ECG waveforms in AUTO/Manual mode, automatically measuring and diagnosing ECG waveform parameters, prompting for “Lead off” and “Lack of paper,” a multi-language interface, AC/DC, rhythm lead selection, printing the P-R interval trend chart and histogram, and case database management. Contec ECG 1200G (12 Channel) Features:  Sync collecting for 12-lead ECG using digital signal processing technique High-quality ECG waveform Auto-analysis and auto-diagnosis have different functions. Up to 1000 cases can be saved in the built-in memory, making it easy to examine and analyse cases. Interface and report available in multiple languages Large display of 3/6/12 for contrastively diagnosis Printing modes and formats can be multiplied in a variety of ways. You can print the P-R interval’s trend chart and histogram. It is possible to change the length of the printed waveform. Standby time of up to 10 hours Various speeds for paper Contec 1200G (12 Channel) Technical Specifications: Floating input circuit protects against defibrillator effect. 12 Leads Lead Standard 8-inch TFT display with 800 x 600 pixels and LED lighting frequency response 0.05Hz – 150Hz (-3dB) >3.2seconds Time Constant >60dB, 100dB CMRR Input Impedance 50MΩ 35Hz EMG Interference Filter (-3dB) Thermal Printing System for Recording Patient Current Leakage 10µA Recording paper specifications: 210mm x 30m roll paper, high speed paper Auto record speeds are 25mm/s and 50mm/s, respectively, with a 5% error margin. Paper speed Auto record: 25mm/s, 50mm/s, error ± 5% Rhythm record: 25mm/s, 50mm/s, error ± 5% Manual record: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error ± 5% Recording configuration according to auto record format and mode, changing leads automatically, measuring and analyzing Sensitivity options include 5,10,20, and 40 mm/mV, with a 5% inaccuracy. 10mm/mV 0.2mm/mV is the standard sensitivity. Rhythm Record Setup according to the format and mode of the rhythm record, automatically measuring and analyzing Recording according to a manual record format and manually changing leads Measurement parameters HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc P axis, QRS Axis, T Axis R(V5), S(V1), R(V5) S(V1) There is a defibrillation and pacing protection circuit in the Product Safety Type Class I CF applied portion. Noise Level <15µVp-p Size 334mm(L) x 320mm (W) x 85mm (H) Enduring Polarization voltage ±500mV Power Supply AC AC:100-240V, 50/60 Hz DC: 14,8V, 3700 mAh rechargeable lithium battery

Memory Type
DDR4

Capacity
8GB (8GBx1)

Multi-Channel Kit
Single Channel Kit

OC Profile Support
Intel XMP 2.0

Tested Speed (Up To) (XMP)
2400 MT/s

Tested Latency (XMP)
15-15-15-35

Tested Voltage (XMP)
1.20V

Registered/Unbuffered
Unbuffered

Error Checking (ECC)
Non-ECC

SPD Speed (Default)
2133 MT/s

SPD Voltage (Default)
1.20V

SHOPPING CART

close
Call Now Button